PSA 5.14 Setup Menu

Figure 5.25 [Watchdog] window

Table 5.34 Displayed and settings items in the [Watchdog] window

Item

 

Description

Software Watchdog

 

 

Watchdog

The user can enable or disable SoftWare Watchdog monitoring:

 

Disable: Disable monitoring

 

Enable: Enable monitoring

 

The default setting is [Disable].

 

 

TimeOut

The user can specify a timeout value in seconds, which is used

 

while the SoftWare Watchdog monitoring is enabled:

 

Range: 60 to 6000 seconds

 

This item can be specified only if [Enable] is selected. The default

 

setting is 3600 seconds.

 

 

Watchdog Action

The user can select from a pulldown list the action to be executed

 

in the event that control is not returned after a timeout:

 

• No Action: Execute no action. Except SEL output.

 

• Reset: Reset the partition

 

• Power Off: Power off the partition forcibly without the normal

 

 

OS termination process (shutdown)

 

• Power Cycle: Forcibly power off the partition and power it on

 

 

again

 

• INIT: Issue an INIT interrupt to the partition

 

You can only specify this item when you select [Enable]. The

 

default is [No Action].

 

 

 

C122-E003-02EN

5-55