MMB

CHAPTER 3 Web-UI Operations

Table 3.37

Displayed and setting items in the [KVM] window

 

 

 

 

 

Item

 

 

Description

Board Information

 

 

 

Status

 

KVM status:

 

 

 

OK: Operating normally

 

 

 

• Not present: Not installed

 

 

 

Degraded: Component failure (The faulty component can be

 

 

 

 

isolated to continue operation.)

 

 

 

Failed: Failure

 

 

 

Power Status

 

KVM power status:

 

 

 

On: Powered on

 

 

 

Standby: Standby mode

 

 

 

Part Number

 

KVM part number

Serial Number

 

KVM serial number

Location LED

 

Location LED status

 

 

 

The three light statuses are as follows:

 

 

 

On: Currently lit

 

 

 

• Off: Currently not lit

 

 

 

Blink: Currently blinking

 

 

 

The LED can be turned on, turned off, or set to blink by clicking a

 

 

 

radio button.

 

 

 

 

Voltage

 

 

 

Sensor

 

Voltage sensor type

Voltage

 

Current voltage reading

Threshold

Warning

 

Lower and upper limits of the warning-level voltage. If no limit is

 

(Low/High)

set, "-" is displayed.

 

 

 

 

 

Critical

 

Lower and upper limits of the critical-level voltage. If no limit is

 

(Low/High)

set, "-" is displayed.

 

 

 

 

 

 

Table 3.38 Button in the [KVM] window

 

 

 

Button

 

Description

Status Clear

 

Clears the error status of the KVM and attempts to use the KVM at

 

 

the next reboot.

 

 

 

(1) Menu operation

[System] [Other Boards] [KVM]

3-60

C122-E003-02EN