MMB

CHAPTER 3 Web-UI Operations

Table 3.35

Displayed and setting items in the [CPCB] window

 

 

 

 

 

Item

 

 

Description

Board Information

 

 

 

Status

 

CPCB status:

 

 

 

OK: Operating normally

 

 

 

• Not present: Not installed

 

 

 

Degraded: Component failure.

 

 

 

Failed: Failure

 

 

 

Power Status

 

CPCB power status:

 

 

 

On: Powered on

 

 

 

Standby: Standby mode

 

 

 

Part Number

 

CPCB part number

Serial Number

 

CPCB serial number

Location LED

 

Location LED status

 

 

 

The three light statuses are as follows:

 

 

 

On: Currently lit

 

 

 

• Off: Currently not lit

 

 

 

Blink: Currently blinking

 

 

 

The LED can be turned on, turned off, or set to blink by clicking a

 

 

 

radio button.

 

 

 

 

Voltage

 

 

 

Sensor

 

Voltage sensor type

Voltage

 

Current voltage reading

Threshold

Warning

 

Lower and upper limits of the warning-level voltage. If no limit is

 

(Low/High)

set, "-" is displayed.

 

 

 

 

 

Critical

 

Lower and upper limits of the critical-level voltage. If no limit is

 

(Low/High)

set, "-" is displayed.

 

 

 

 

 

Clock

 

 

 

 

Clock#0 to Clock#1

 

System clock status:

 

 

 

OK: Operating normally

 

 

 

Failed: Failure

 

 

 

 

 

 

Table 3.36 Button in the [CPCB] window

 

 

 

Button

 

Description

Status Clear

 

Clears the error status of the CPCB and attempts to use the CPCB

 

 

at the next reboot.

 

 

Reference: You can clear the CPCB error status and specify that

 

 

the CPCB be reused at the next reboot. If an error is

 

 

detected again during reboot, the CPCB will be placed

 

 

again in an error status.

 

 

 

3-58