MMB

CHAPTER 3 Web-UI Operations

Item

 

Description

Redundancy

Redundancy statuses of DC-to-DC Converters 0 and 1:

 

 

• Redundant: Redundancy is maintained.

 

 

Non-redundant: Sufficient Resources: Redundancy is lost, but

 

 

 

there are enough converters to continue system operation.

 

 

Non-redundant: Insufficient Resources: Redundancy is lost, and

 

 

 

there are not enough converters to continue system operation.

 

 

DDC#00 to #01

Statuses of DC-to-DC Converters 0 and 1:

 

 

OK: Operating normally

 

 

• Not present: Not installed

 

 

• Configuration error: Configuration error

 

 

Failed: Failure

 

 

Redundancy

Redundancy statuses of DC-to-DC Converters 02 to 04.

 

 

These statuses are displayed in the same way as the redundancy

 

 

statuses of DC-to-DC Converters 00 and 01.

 

 

DDC#02 to #04

Statuses of DC-to-DC Converters 02 to 04.

 

 

These statuses are displayed in the same way as the statuses of DC-

 

 

to-DC Converters 00 and 01.

 

 

Redundancy

Redundancy statuses of DC-to-DC Converters 05 and 06.

 

 

These statuses are displayed in the same way as the redundancy

 

 

statuses of DC-to-DC Converters 00 and 01.

 

 

DDC#05 to #06

Statuses of DC-to-DC Converters 05 and 06.

 

 

These statuses are displayed in the same way as the statuses of DC-

 

 

to-DC Converters 00 and 01.

 

 

Redundancy

Redundancy statuses of DC-to-DC Converters 07 to 13.

 

 

These statuses are displayed in the same way as the redundancy

 

 

statuses of DC-to-DC Converters 00 and 01.

 

 

DDC#7 to #13

Statuses of DC-to-DC Converters 07 to 13.

 

 

These statuses are displayed in the same way as the statuses of DC-

 

 

to-DC Converters 00 and 01.

 

 

SSM

Slow-start circuit status:

 

 

OK: Operating normally

 

 

Failed: Failure

 

 

 

Voltage

 

 

Sensor

Voltage sensor type

Voltage

Current voltage reading

Threshold

Warning

Lower and upper limits of the warning-level voltage. If no limit is

 

(Low/High)

set, "-" is displayed.

 

 

 

 

Critical

Lower and upper limits of the critical-level voltage. If no limit is

 

(Low/High)

set, "-" is displayed.

 

 

 

 

3-38

C122-E003-02EN