MMB

CHAPTER 3 Web-UI Operations

Item

Description

Status

Fan status:

 

• OK: Operating normally

 

• Not present: Not installed

 

• Failed: Fan failure

 

 

Fan Speed(rpm)

Fan speed (rpm).

Threshold(rpm)

Lower limit of the fan speed (Any speed lower than this setting is

 

abnormal.)

 

 

 

Table 3.21 Button in the [Fans] window

 

 

 

Button

 

Description

Status Clear

 

Click the [Status Clear] button to display the [Fans Status Clear]

 

 

window. This window enables clearing of the fan statuses.

 

 

 

(1)Menu operation

[System] [Fans]

(2)GUI operation

1Click the [Status Clear] button.

The [Fans Status Clear] window is displayed.

2Follow the clearing process in the [Fans Status Clear] window. The fan statuses are cleared.

3.2.9.1Fans Status Clear window

Once an abnormality is detected in a fan, the fan remains in the abnormal status until the fan is replaced or the abnormal status is cleared.

The abnormal status of a fan can be cleared using the [Fans Status Clear] window.

Note: After the abnormal status of a fan is cleared, if an abnormal fan speed is detected in the fan, the fan is placed in the [Failed] status again. Clearing the status of a fan with an abnormal fan speed does not change its status from [Failed].

3-30