APPENDIX B — SCS/DCA COMMAND SUMMARY

Page B-23

 

 

 

Command:

Set Justify Mode (SJM)

 

Format:

2B D2 nn 0D st pr

 

Printers:

3812, 5219

 

Action:

Set Justify Mode is used to activate and deactivate

 

justification.

 

The st parameter specifies whether justify mode is to be activated or deactivated. An st value of 00h means no change. An st value of 01h means activate justify mode. An st value of 02h means deactivate justify mode.

The pr parameter specifies the percentage of white space at the end of the field to be redistributed within the field. A pr value of 00h means no change.

Allowed values of pr are 00h, 32h (50%) and 64h (100%).

When justification is active, Justify Text Field (JTF) is not allowed.

When justification is active, subsequent text is justified between the left and right margins.

Lines ended with any of the following combinations of commands are considered to be the last line of a paragraph and are not justified:

NL (or IRS) & NL (or IRS); RNL (or IRT); NL (or IRS)

&LF; NL (or IRS) & HT; NL (or IRS) & Indent Tab; NL (or IRS) & Space; NL (or IRS) & Numeric Space; NL (or IRS) & Required Space; NL (or IRS) & BS; NL (or IRS)

&UBS; NL (or IRS) & CR; NL (or IRS) & RLM; NL (or IRS) & NBS; Required Form Feed.

 

Lines of text that extend past the right margin are not

 

justified.

IBMEMUL:

Same as IBM.

 

The OPTIMA allows any percentage rule: 00h (no

 

change), and 01h (1%) to 64h (100%).

 

The OPTIMA turns off justify mode (as set by Set Justify

 

Mode) upon receiving this command.

 

The OPTIMA performs all calculations necessary to

 

perform the justification on the target printer.

275EMUL:

No operation.

 

 

Page 208
Image 208
Agilent Technologies 5250 user manual Perform the justification on the target printer