DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
977Trunk Group
17
placed the original call. The caller will hear 3 short, quick rings. The caller
doesn’t need to do anything but pick up the handset and wait: the switch
remembers the number the caller dialed and automatically completes the call.
This field appears when the Direction field is outgoing or two-way.
Tip:
Enter
0
for DCS trunks.
Country
This field is administered at installation and sets numerous parameters to
appropriate values for the public network in which the switch operates. For
example, the value of this field, with the values of the Trunk Termination and the
Trunk Gain fields, determines the input and trans-hybrid balance impedance
requirements for ports on TN465B, TN2146, and TN2147 circuit packs.
This field appears for the trunk groups that connect DEFINITY ECS to a central
office in the public network — CO, DID, DIOD, FX, and WATS trunk groups.
!CAUTION:
Don’t change this field. If you have questions, contact your Lucent
representative.
Valid entries Usage
0 to 100 Enter the number of outgoing calls that you want to be held
waiting when all trunks are busy.
Valid entries Usage
1 to 25 Set at installation.
11 If the Country field is 11, DEFINITY ECS is administered for
Public Network Call Priority (Call Retention and Rering).
14 If the Country field is 14 and the Group Type is DID or DIOD,
the CO Type field appears.