Screen reference
656Feature-Related System Parameters
17
Special Dial Tone
Special dial tone notifies an analog-phone user if certain features are still active
when the user goes off-hook. These features include:
■Call Forwarding
■Send All Calls
■Do Not Disturb
Refer to the DEFINITY ECS Application Notes for Type Approval for more
information.
Long Hold Recall Timer (seconds)
You can administer the system to remind a user that a call has bee n on hold for too
long.
Reset Shift Timer (seconds)
Used only for station-to-station calls or private network calls using ISDN trunks.
Station Call Transfer Recall Timer
Allows a user-transferred call (station-to-station, a trunk call, or a DCS call) to
re-terminate with priority ringing back to the station user who initiates the transfer
operation if the transfer-to party does not answer the call within the administered
Station Call Transfer Recall timer.
Valid entries Usage
y/n Enter y to use the Special Dial Tone. You must have a TN2182
circuit pack.
Valid entries Usage
0 - 999 Enter a number between 0 and 999; 0 deactivates the timer.
This value is the number of seconds a call can be on hold
before the system re-alerts the user to remind them of the call.
Valid entries Usage
0 - 255 Specifies the number of seconds that reset shift dial tone is
audible before busy tone is heard. Enter 0 to disable this
feature.
Valid entries Usage
0 - 999 Enter the time in seconds before a call redirects back to the
station user who initiated the transfer operation. Enter 0 to
disable this feature.