DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
575Data modules
17
Default Data Applications
Used with 7500 and World Class BRI Data Modules. Used to identify mode to be
Used with originating data calls when the m ode is not specified with the calling
parameters. This mode is also used for terminating trunk calls that do not have
bearer capability specified or administered connections. Refer to ‘‘Generalized
route selection’’ on page 1340 for additional information.
MM Complex Voice Ext:
Used with 7500 and World Class BRI Data Modules. This display-only field
contains the number of the associated phone in the multimedia complex. It only
appears when the Multimedia field is y. This field is left blank until you enter the
data module extension in MM Complex Data Ext field on the Station screen . Once
you complete the field on the Station screen, these two extensions are associated
as two parts of a one-number complex, which is the extension of the phone. Valid
values conform to your dial plan.
Field descriptions for page 2
Screen 65. Data Line Data Module — if KYBD Dialing is y
Valid entries Usage
M0 Mode 0. Use this setting for a WCBRI endpoint used as an
administered connection.
M1 Mode 1
M2_A Mode 2 asynchronous
M2_S Mode 2 synchronous
M3/2 Mode 3/2 adaptable
blank
change data-module 30 DATA MODULE Page 2 of 2
CAPABILITIES
KYBD Dialing? y Configuration? n
Busy Out? n
SPEEDS
Low? y 1200? y 4800? y 19200? y
300? y 2400? y 9600? y Autoadjust? n
OPTIONS
Permit Mismatch? n Dial Echoing? y
Disconnect Sequence: two-breaks Answer Text? y
Parity: even Connected Indication? y