DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
510CDR System Parameters
17
Primary Output Format
Controls the format of the call records sent to the primary output device.
Primary Output Extension
This field determines where the switch sends th e CDR records, and is required if
you specify a Primary Output Format.
Valid entries Usage
customized Use this option if you have special call accounting needs that
standard record formats do not accommodate. If you use a
customized record format, you need to have call accounting
software that is also customized to receive these records.
Consult with your call accounting vendor before using this
option.
printer Use printer if you are sending the call detail records to a
printer rather than to a record collection or call accounting
system.
59-char
expanded
lsu
lsu-expand
int-direct
int-isdn
int-process
teleseer
unformatted
The remaining formats are standard record formats. The one
you use must be compatible with your call accounting
software. Verify this through your vendor or the accounting
system documentation.
Valid entries Usage
eia If you use the EIA port to connect the CDR device, enter
eia. This is not a valid option on G3r systems.
Extension number This is the ext ensio n of the dat a modul e (if us ed) that links
the primary output device to the switch.