DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
879Security-Related System Parameters
17
Screen 183. Security-Related System Parameters for G3si and G3csi
SVN Station Security Code Violation
Notification Enabled
Station Security codes are used to validate logins to a particular extension (for
example, a home agent using an extender, or two part-time wor kers using the same
telephone, but different extensions, through personal station access.) Enter y here
to establish parameters for this.
Minimum Station Security Code Length
This determines the minimum required len g th of the Station Security Codes that
you enter on the Station screen.
Security Code for Terminal Self Administration
Required
Valid entries Usage
3–8 Longer codes are more secure. If station security codes are
used for external access to telecommuting features, the
minimum length should be 7 or 8.
Valid entries Usage
y/n Enter y to indicate that a security code is require d.
change system-parameters security Page 2 of 2
SECURITY-RELATED SYSTEM PARAMETERS
SECURITY VIOLATION NOTIFICATION PARAMETERS
SVN Station Security Code Violation Notification Enabled? y
Originating Extension: _____ Referral Destination: _____
Station Security Code Threshold: 10 Time Interval: 0:03
Announcement Extension: _____
STATION SECURITY CODE VERIFICATION PARAMETERS
Minimum Station Security Code Length: 4
Security Code for Terminal Self Administration Required? y
ACCESS SECURITY GATEWAY PARAMETERS
MGR1? n INADS? n
EPN? n NET? n