DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
1025Trunk Group
17
Unacceptable Threshold - Min - 1004 Hz Loss
Unacceptable Threshold - Max - 1004 Hz Loss
Marginal Threshold - -Dev - 404 Hz Loss
Marginal Threshold - +Dev - 404 Hz Loss
Unacceptable Threshold - -Dev - 404 Hz
Valid entries Usage
-2 to 21 Enter the minimum signal loss allowed for a 1004 Hz test tone
(in dB) before a trunk is reported as unacceptable. A larger dB
value is more restrictive.
Valid entries Usage
0 to 21. Enter the maximum signal loss allowed for a 1004 Hz test t one
(in dB) before a trunk is reported as unacceptable. A smaller
dB value is more restrictive.
Valid entries Usage
0 to 9Enter the maximum negative deviation of measu red loss at 404
Hz from the 1004 Hz test tone noise level (in dB) allowed
before reporting a trunk as out of tolerance. Smaller dB values
are more restrictive.
Valid entries Usage
0 to 9Enter the maximum positive deviation of measured loss at 404
Hz from the 1004 Hz test tone loss level (in dB) allowed before
reporting a trunk as out of tolerance. Smaller dB values are
more restrictive.
Valid entries Usage
0 to 9Enter the maximum negative deviation of measured loss at
404 Hz from the 1004 Hz test tone loss level (in dB) allowed
before reporting a trunk as unacceptable. Smaller dB values
are more restrictive.