DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
1018Trunk Group
17
Outgoing Disconnect Send (msec)
This field is administrable only if the Trunk Signaling Type field is dis and the
trunk group Direction field is two-way or outgoing. Only TN2140 ports receive
this timer.
Seize Ack Send (msec)
This field appears only if the Trunk Signaling T ype fie ld is dis and the trunk group
Direction field is incoming or two-way. Only TN2140 ports receive this timer.
Incoming Disconnect Send (msec)
This field is only administrable if the Trunk Signaling Type field is dis and the
trunk group Direction field is incoming or two-way. Only TN2140 ports receive
this timer.
Tone (msec)
This field appears only if the Trunk Signaling T ype field is blank. All CO, DIOD,
and Tie circuit packs that accept administrable timers accept this timer. This timer
is also sent to the following circuit packs: TN464B (or later), TN767, TN436B,
TN459B, TN2146, TN2199, TN429, TN2184 ports in a DID trunk group.
Valid entries Usage
100 to 9900 in
increments of
100
Enter the duration of the forward release signal your switch
sends at the end of outgoing calls.
Valid entries Usage
10 to 990 in
increments of
10
Enter the duration of the seizure acknowledgment signal your
switch sends in response to an incoming seizure.
Valid entries Usage
500 to 1200 in
increments of
100
Enter the duration of the backward release signal your switch
sends at the end of an incoming call.
Valid entries Usage
20 to 2550 in
increments of
10
Enter the duration of a DTMF tone sent when a button on a
hybrid phone is pressed.