1385IP trunk service
20
Possible sites for originating a call to Terminating Site-1 are labeled O1 (for
Originating Site-1), O2, and so on. A call can terminate on a telephone connected
to the switch at T1, or it can be routed “off-premise” to terminating sites T2, T3,
or T4. Since the IP calls received at T ermina ting Si te-1 are di aled t he same way a s
conventional calls, even if no off-premise dialing is configured, the telephone
number received will differ depending on where the call originated:
Calls from Originating Site-O1 (which is within the same area code as T1)
contain only exchange and extension portions.
Calls from O2 (which is within the same count ry, but in a different area
code than T1) contain a long distance access code and an area code, as well
as an exchange and an extension.
Calls from O3 contain an international access code, a country code, a n area
code, an exchange and an extension.
In all three cases, the DEFINITY IP Trunk application at Terminating Site-1
changes the digits in the telephone number received to match what the switch
expects to receive for a call to one of its extensions.