DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
636Feature-Related System Parameters
17
DID/Tie/ISDN Intercept Treatment
Messaging Service Adjunct (MSA) Connected
Internal Auto-Answer of
Attd-Extended/Transferred Calls
This only applies to digital telephones (except BRI) with a headset or
speakerphone capability.
Automatic Circuit Assurance (ACA) Enabled
If Automatic Circuit Assurance (ACA) Enabled is n, associated ACA fields will
not display.
Valid entries Usage
A recorded
announcement
extension
Toll charges do not apply to DID and private network calls
routed to an announcement.
attd For system security, Lucent recommends entering attd in this
field. This routes intercept calls to the attend a nt and, if the
attendant receives several of these, they will know a problem
exists.
Valid entries Usage
y Enter y if AUDIX Voice Power MSA is connected to the
system.
n
Valid entries Usage
attd-extended Enter attd-extended to enable IAA for only attendant e xtended
calls.
both Enter both to enable IAA for station trans ferred and attendant
extended calls.
none Enter none to disable IAA for all calls.
transferred Enter transferred to enable IAA for only st ation transferred
calls.