DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Managing data calls
397Data Call Setup
15
ISDN-BRI data modules
Data-terminal dialing
A user can set up and disconnect data calls directly from a data terminal without
using a telephone as follows:
1. The user presses ENTER a few times. If the CMD: prompt does not appear,
the user presses BREAK A + T at the same time, and then presses ENTER.
2. At the CMD: prompt, the user types and presses ENTER.
3. To disconnect, the user enters +++. At the CMD: prompt, the user types
end and presses ENTER.
Telephone dialing
To make a data call, an ISDN-BRI phone user presses the data button on the
terminal, enters the number on the dial pad, and then presses the data butto n agai n.
The following data functions are not available on ISDN-BRI phones:
One-Button Transfer to Data
Return-to-Voice
Data Call Preindication
Voice-Call Transfer to Data and Data-Call Transfer to Voice
The system handles all presently defined BRI bearer data-call requests. Some
capabilities that are not supported by Lucent terminals are provided by
non-Lucent terminals. If the switch does not support a capability, a proper cause
value returns to the terminal.
BRI terminals receive a cause or reason code that identifies why a call is being
cleared. The BRI data module converts certain cause values to text messages for
display.
In a passive-bus multipoint configuration, the system s uppor t s tw o BRI endpoints
per port, thus doubling the capacity of the BRI circuit pack. When you change the
configuration of a BRI from point-to-point to multipoint, the original endpoint
does not need to reinitialize. Only endpoints that support service profile identifier
(SPID) initialization can be administered in a multipoint configuration.
Analog modems
When a telephone user places a data call with a modem, the user dials the
data-origination access code assigned in the system before dialing the endpoint.