984Trunk Group
17
Trunk Type (in/out)
Use this field to control the seizure and start-dial signaling used on this trunk
group. The setting of the Trunk Signaling T ype f i eld can af fe ct the ent ries al lowed
in this field. In addition, settings may differ for incoming and outgoing trunks.
Valid entries Usage
auto
cont
delay
disc
immed
wink
There are numerous valid entries for this field: use the online
help in the switch administration software to view all the
possible combinations. Here are what the elements used in
those combinations mean:
auto — Used for immediate connection to a single preset
destination (incoming CO trunks, for example). No digits
are sent, because all calls terminate at the same place.
cont — Continuous signaling is used with Italian E&M tie
trunks. The switch seizes a trunk by sending a continuous
seizure signal for at least the duration specified by the
Incoming Seizure Timer. Refer to ‘‘Trunk Signaling Type’’
on page 974 for more information.
delay — The sending switch does not send digits until it
receives a delay dial signal (an off-hook signal foll o wed b y
an on-hook signal) from the far-end switch, indicating that
it’s ready to receive the digits.
disc —Discontinuous signaling is used with Italian tie
trunks that use E&M signaling. The switch can seize a
trunk by sending a single, short signal for the duration
specified by the Normal Outgoing Seize Send field.
However, with the Three-Way Seizure option the calling
switch can also send routing information to the called
switch by sending one or a series of brief seizure signals.
wink — The sending switch does not send digits until it
receives a a wink start (momentary off-hook) signal from
the far-end switch, indicating that it’s ready to receive the
digits.
immed — The sending switch sends digits without waiting
for a signal from the far-end switch.
2-wire-ac These entries are used with CO trunks in Russia: enter the type
of connection to your central office. Check with you network
service provider if you don’t know what type of connection
they’re using. To use these entries, the Country field must be
15 and the CO trunks must use ports on a TN2199 circuit
board.
2-wire-dc
3-wire