DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
475Administered Connection
17
Duration
Enter the period of time that the scheduled AC should remain active. This period
is specified in two fields separated by a colon. The maximum duration is 167
hours and 59 minutes (that is, 1 minute less than 1 week). Only appears if the
Continuous field is n.
Miscellaneous Parameters
Alarm Type
Enter the type of alarm to be generated if the AC cannot be initial ly establ ished, or
fails and cannot be reestablished, and the number of consecutive failures equals
the alarm threshold. All AC alarms and the errors that caused the alarms are
recorded in the system’s alarm and error log. In addition, a status lamp associated
with an attendant console or phone feature button (ac-alarm) may be used to
indicate the AC alarm.
Valid entries Usage
000 through 167 For the hour field.
00 through 59 For the minute field.
Valid entries Usage
major Failures that cause critical degradation of service and require
immediate attention.
minor Failures that cause some degradation of service, but do not
render a crucial portion of the system inoperable. This
condition requires action, but its consequences are not
immediate. Problems might be impairing service to a few
trunks or stations or interfering with one feature across the
entire system.
warning Failures that cause no significant degradation of service or
failures in equipment external to the system. Warning alarms
are not reported to the attendant console or INADS.
none The alarm notification may be disabled for this AC.