DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Managing data calls
436Setting up CallVisor ASAI
15
Setting up CallVisor ASAI
CallVisor Adjunct-Switch Applications Interface (ASAI) can be used in the
telemarketing and help-desk environments. It is used to allo w adjunct app licati ons
to monitor and control resources in the DEFINITY ECS.
Before you start
On the System Parameters Customer-Options screen, verify the:
ASAI Interface field is y. If not, contact your Lucent representative.
ASAI Proprietary Adjunct Links field is y if the adjunct is running
the CentreVu Computer Telephony.
Instructions
To set up CallVisor ASAI:
1. Type add station
nnnn
and press RETURN, where nnnn is the extension you
want to assign to the ASAI adjunct.
The Station screen appears.
2. In the Type field, type
asai if this adjunct platform is other than Cent reVu Computer
Telephony, for example, IBM CallPath.
adjlk (ASAI proprietary adjunct link) if this is for t he CentreVu
Computer Telephony using the Telephony Services Application
Programming Interface (TSAPI).
Page 1 of X
STATION
Extension: 1014 Lock Messages? n BCC: 0
Type: asai Security Code: ______ TN: 1
Port: 01A0702 Coverage Path 1: ___ COR: 1
Name: __________________________ Coverage Path 2: ___ COS: 1
Hunt-to-Station: ____
STATION OPTIONS
Data Module? n Personalized Ringing Pattern: 1
Display Module? n Message Lamp Ext: 1014
MM Complex Data Ext: ____