Screen reference
574Data modules
17
Default Mode
Used with 7500 and World Class BRI Data Modules. Used to identify the data
mode.
Default Speed
Used with 7500 and World Class BRI Data Modules. Used to identify the data
rate.
ASSIGNED MEMBER
Ext and Name
Used with Data Line, Announcement, Netcon, Processor/Trunk, Processor
Interface, and System Port Data Modules. Appears the extension number and
name of the user (previously administered) with associated Data Extension
buttons who shares the module.
DATA MODULE CAPABILITIES
Default ITC
Used with 7500 and World Class BRI Data Modules.
Valid entries Usage
sync Synchronous
async Asynchronous
Valid entries Usage
1200
2400
4800
19200
56000
64000 Can be entered when the Default Mode field is sync.
Valid entries Usage
restricted For a WCBRI endpoint used as an administered connection.