DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Features and technical reference
1230Call Detail Recording
20
Call Detail Record formats
Customized format
You can use the customized record format to make up your own call record. You
can determine the data elements you want and their positions in the record. This
method may be necessary if you want to include certain data elements that are not
available on the standard formats.
However, whatever device you use to interpret the CDR data needs to be
programmed to accept these formats. Consult your Lucent Technologies
representative before using a custom record format.
Table 27. CDR Data format — TELESEER
Position Data Field Description
1–3 Space
4–5 Time of day-hours
6–7 Time of day-minutes
8 Duration-hours
9–10 Duration-minutes
11 Duration-tenths of minutes
12 Condition code
13–15 Access code dialed
16–18 Access code used
19–33 Dialed number
34–38 Calling number
39–53 Account code
54 FRL
55 IXC
56–58 Incoming circuit ID
59–61 Outgoing circuit ID
62 Feature flag
63–69 Authorization code
70–76 Space