DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
836Multifrequency-Signaling-Related System Parameters
17
Tones from CO on Incoming Forward Calls —
Group I
Message codes 11 to 15 display. (Numbers 1 through 10 are assigned to the di git s
of the destination telephone number.) Assign a meaning to each code.
Tones to CO on Incoming Backward Calls —
Group B
This field does not appear if the Do Not Send Group B Signals to CO field is y.
Message codes between 1 and 15 display. Assign a meaning to each code.
Field descriptions for page 4
The fields shown on this page define the meaning of MFC tones for calls
originated at the PBX. Refer to ‘‘Definitions of Group I, II, A, and B signals’’ on
page 839 for more information.
Page 4 of the Multifrequency-Signaling-Related System Parameters screen only
appears if Outgoing Call Type is group-ii-mfc or mfe.
Valid entries Usage
Refer to ‘‘Definitions of Group I, II, A, and B signals’’ on page 839 for signal
type.
Valid entries Usage
busy Refer to ‘‘Definitions of Group I, II, A, and B signals’’ on page
839 for signal type.
congestion
free
mct
tariff-free
tie-free
toll-busy
intercept