DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
1019Trunk Group
17
Pause (msec)
THis field is administrable only if the Trunk Signaling Type field is blank. All
CO, DIOD, and tie circuit packs that accept administrable timers accept t his timer.
However, this timer is sent only to the following circuit packs: T N464B (or later),
TN767, TN436B, TN459B, TN2146, TN2199, and TN2242, and TN429 and
TN2184 ports in a DID trunk group.
PPS
NOTE:
The TN439, TN458, TN497, TN747Bv12 (or later), and TN767 circuit
packs only send rotary pulses at 10 pps.
Make (msec)
Valid entries Usage
20 to 2550 in
increments of
10
Enter the minimum acceptable interval (pause) be tween DTMF
tones sent from a hybrid phone.
Valid entries Usage
10 Enter the rate (pulses per second) at which outgoing rotary
pulses are sent over this trunk group.
20
Valid entries Usage
Enter the duration of the make interval (the pause between pulses) while the
system is outpulsing digits using dial pulse signaling. The field cannot be blank.
20 to 80 in
increments of 5 If the PPS field is 10, the sum of the Make (msec) and Break
(msec) fields must equal 100.
10 to 40 in
increments of 5 If the PPS field is 20, the sum of the Make (msec) and Break
(msec) fields must equal 50.