DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
902Station
17
Per Station CPN - Send Calling Number
Port
Enter 7 characters to specify a port, or an x. If this extension is regi ste re d as a n IP
softphone endpoint, this field will display S00000.
For DCP sets, the port can only be assigned once. ISDN-BRI provides a
multipoint configuration capability that allows a previously assigned port
to be specified more than once as follows: 2 stand-a lon e voice endpoints, 2
stand-alone data endpoints, or 1 integrated voice and data endpoint.
However, for the following cases, the port is assumed to be fully assig ned:
Maximum number of users (currently 2) are assigned on the port.
One of the users on the port is a fixed TEI station.
6HLL
7HLH
8LHL
Valid entries Usage
yAll outgoing calls from the station will deliver the Calling
Party Number (CPN) information as “ Presentation Allowed.”
nNo CPN information is sent for the call.
rOutgoing non-DCS network calls from the station will
deliver the Calling Party Number informa tion as
“Presentation Restricted.”
blank The sending of CPN information for calls is controlled by
any administration on the outgoing trunk group the calls are
carried on.
Valid entries Usage
01 through 44 (G3r) First and second numbers are the cabinet number
01 through 03 (G3si)
A through EThird character is the carrier
01 through 20 Fourth and fifth characters are the slot number
01 through 32 Sixth and seventh characters are the circuit number
xIndicates that there is no hardware associated with the
port assignment. Use for IP softphones.
Valid entries Usage