DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
472Administered Connection
17
Field descriptions for page 1
Screen 32. Administered Connection screen
Connection Number
This is a display-only field showing an unassigned AC number when the screen is
accessed using an administration command such as change or display.
Enable
Provides the administered connection.
Originator
Enter the assigned access endpoint/data module extension.
Data Line circuit pack
Asynchronous EIA 232C compatible equipment
Digital Line circuit pack connections, including:
MPDM (700D), MTDM (700B, 700C, 700E), 7400D data module
7400A, 7400B, 7400C HSL, 8400B data module
Valid entries Usage
yIndicates an attempt will be made to establish the AC when the
AC is due to be active.
nThe AC will not be made or if it is up, it will drop.
change administered-connection Page 1 of 1
ADMINISTERED CONNECTION
Connection Number: 1 Enable? y
Originator: ______
Destination: __________________________________
Name: __________________
AUTHORIZED TIME OF DAY
Continuous? n
Sun? n Mon? n Tue? n Wed? n Thu? n Fri? n Sat? n
Start Time: 00:00
Duration: 000:00
MISCELLANEOUS PARAMETERS
Alarm Type: warning Alarm Threshold: 5
Retry Interval: 2
Priority: 5 Auto Restoration? y