DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
614DS1 Circuit Pack
17
Alarm When PRI Endpoint Detached
Use this field for DS1 circuit packs connected to Roll-About Video equipment.
This field appears only when the Connect field is line-side.
Field descriptions for page 2
Screen 76. DS1 Circuit Pack
!CAUTION:
Customers: Do not change fields on this page withou t assistance from
Lucent Technologies or your network service provider.
Page 2 does not appear for all DS1 circuit packs. For those circuit packs that
support it, this page appears only when:
the version is V3 or greater
the Framing Mode field is esf or the Near-end CSU Type field is
integrated.
Valid entries Usage
y/n Enter y if you want the switch to generate an alarm when the
DS1 board detects a loss of signal (for example, if the video
equipment is disconnected).
add ds1 xxxxxx
DS1 CIRCUIT PACK
ESF DATA LINK OPTIONS
Network Management Protocol:
Send ANSI-T1.403 One-Second Performance Reports?
Far-end CSU Address:
INTEGRATED CSU OPTIONS
Transmit LBO:
Receive ALBO:
Upon DTE LOS:
CPE LOOPBACK JACK OPTIONS
Supply CPE Loopback Jack Power?