DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
1011Trunk Group
17
Incoming Disconnect (msec)
The field appears only for an incoming or two-way trunk group when the Trunk
Signaling Type field is either blank or cont.
Outgoing Disconnect (msec)
Cama Outgoing Dial Guard (msec)
This field appears when Group Type is cama (the trunk group type used for
emergency 911 service).
Incoming Dial Guard (msec)
NOTE:
This timer is never sent to TN429 ports.
Valid entries Usage
50 to 2550 in
increments of
10
Enter the minimum valid duration of a disconnect signal for an
incoming call. The switch will not recognize shorter disconnect
signals. This field cannot be blank. For Brazil pulsed E&M
signaling, use 600.
Valid entries Usage
50 to 2550 in
increments of
10
Enter the minimum valid duration of a disconnect signal for an
outgoing call. The switch will not recognize shorter disconnect
signals. This field cannot be blank. This timer begins timing
when a disconnect signal is detected on an outgoing call and
resets when the signal is no longer detected. If the timer
expires, the trunk drops. For Brazil pulsed E&M signaling, use
600.
Valid entries Usage
25 to 6375 in
increments of
25
Enter the minimum interval between the receiving switch’s
seizure acknowledgment and the outpulsing of digits by this
switch.
Valid entries Usage
10 to 2550 in
increments of
10
Enter the minimum acceptable interval betwee n the detection
of an incoming seizure and the acceptance of the first dig it. The
switch will not accept digits before this timer expires.