DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
608DS1 Circuit Pack
17
The default value of the field changes depending upon which value the Interface
field contains.
!CAUTION:
It is critical that administration on this switch co rrectly pairs with the
administration of the far-end switch. If the far-end is administered as the b
side, this field should be set to a regardless of whether the layer 2
designation is peer-master or peer-slave, and vice versa.
Protocol Version
In countries whose public networks allow multiple layer 3 signaling protocols for
ISDN-PRI service, this field selects the protocol that matches your network
service provider’s protocol. Refer to ‘‘Public network signalin g adminis trat ion fo r
ISDN-PRI Layer 3’’ on page 1321 to see which countries support which
protocols.
This field appears only when:
The Signaling Mode field is isdn-pri and the Connect field is network.
The Signaling Mode field is isdn-pri, the Connect field is pbx, and the
Interface field is user or network.
!WARNING:
The AT&T Switched Network Protocol does not support restricted displays
of connected numbers. Therefore, if you administer th e 1a
country-protocol/protocol-version combination on the DS1 screen, you
cannot set the Send Connected Number field to
r
(restricted) on the
ISDN-PRI Trunk Group screen, as this causes display problems.
Valid entries Usage
aEnter a if the Interface field is peer-master (this
switch overrides the far-end when glare occurs).
bEnter b if the Interface field is peer-slave (this
switch releases the contested circuit and looks for
another when glare occurs).
Valid entries Usage
aThe entry in this field must match the protocol used by your
network service provider, so work with your vendor to
determine the appropriate entry.
b
c