DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
508CDR System Parameters
17
Ext Code
CESID
Total Length
CDR System Parameters
Use the Call Detail Recording (CDR) System Parameters screen to set parameters
for the types of calls you want to record and how to format the information. You
can use CDR records to determine call costs, diagnose problems, detect abuse, and
optimize your network.
Valid entries Usage
Up to 5 digits Enter the leading digits or all of the digits in the extension for
the specified CESID. If the extension length is greater than the
number of digits in the extension code, the extension code will
be interpreted as a block of digits. For example, if the
extension length is 4 and the extension code is 11, the CESID
will serve extensions 1100 through 1199. The Ext Code 11 is
for a DID block. An Ext Code of 126 might point a non-DID
block to a nearby DID extension 5241666.
Valid entries Usage
1 to 11 digits Enter the number that will be used to identify the calling
terminal within an emergency service system. This field may
represent a prefix to an extension or the ent ire CESID.
Valid entries Usage
1–16 Enter the total number of digits to send.