DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
772ISDN Numbering — Private
17
group. If a DS1 circuit pack appears in more than one signaling group, then the
Sig Grp field cannot be left blank. One of the signaling group members must be
entered. Valid values are 1–0 or 1–166 depending on the amount of system
memory.
Related topics
Refer to ‘‘ISDN service’’ on page 1394 for detailed information about Integrated
Services Digital Network trunks.
Refer to ‘‘DS1 Trunk Service’’ on page 1317 for detailed information on DS1.
ISDN Numbering — Private
This screen supports Private Numbering Plans (PNP). It allows you to specify the
digits to be put in the Calling Number information element (IE), the Connected
Number IE, and the QSIG Party Number for extensions in the Private Numbering
Plan.
DEFINITY ECS supports private-network numbers up to 15 digits long. If the
total number — including the level 1 and 2 prefixes, the PBX identifier, and the
extension — is more than 15 digits long, neither QSIG PartyNumbers nor the
information elements are created or sent.
Screen 122. ISDN Number — Private Format
change isdn private-numbering Page 1 of 1
ISDN NUMBERING - PRIVATE FORMAT
Network Level: _ PBX Identifier: ____
Level 2 Code: _____ Deleted Digits: _
Level 1 Code: _____