Screen reference
567Data modules
17
MM Complex Voice Ext
Used with 7500 and World Class BRI Data Modules. This field contains the
number of the associated phone in the multimedia complex. This field appears
only after you set the Multimedia field to y. This field is left blank until you enter
the data module extension in MM Complex Data Ext on the Station screen.
Secondary data module
Used with Processor/Trunk Data Modules. Appears only when the Type field is
pdm. The primary data module must be administered before the secondary data
module may be added. If the Port field is X, the Secondary data module field
cannot be y.
Baud Rate
Used with X.25 Data Modules. The maximum raw data transmission speed.
Valid entries Usage
Valid values
conform to your
dial plan
Once you complete the field on the station screen, these two
extensions are associated as two parts of a one-number
complex, which is the extension of the telephone.
Valid entries Usage
yThis PDM is the secondary data module used for Dual
I-channel AUDIX networking.
nThis is the primary PDM, or if this data module is not used for
AUDIX networking.
Valid entries Usage
300
1200
2400
4800
9600
19200
switched You can enter this if the Cable Type field is none on the
PGATE screen.