DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Features and technical reference
1192Busy Verification
20
Considerations
A busy verification cannot be made to an analog extension that is w aiting to
be answered at another extension. A call must be answered before it can be
verified.
If your country requires a tone other than 440 Hz, use the Intrusion feature
rather than Verify to verify telephones.
The system does not provide bridging when you verify UCD and DDC
groups or RLTs.
You cannot make outgoing test calls on DID trunks.
You can verify an extension that is administered without hardware
(X-ported). In this case, the system generates reorder tone.
Table 16. Verification of a Trunk
Trunk Status System Response Result
The trunk is idle
and incoming.
The system generates
confirmation tone.
Verification is complete.
Anyone can use the trunk.
The trunk is idle
and outgoing.
The system generates dial
tone.
Verification is complete.
Anyone can use the trunk.
The trunk is busy
with an active call.
The system bridges the Verify
originator onto the call.
The system generates a
warning tone to all active
parties and repeats the tone
every 15 seconds while the
Verify originator remains
bridged onto the call.
Verification is complete.
The trunk is in use.
The trunk is out of
service.
The system generates reorder
tone.
Verification is denied.