DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
949System Parameters OCM Call Classification
17
Global Classifier Adjustment (dB)
Enter a number to specify the dB loss adjustment.
USA Default Algorithm
USA SIT Algorithm
Field descriptions for page 2
Screen 199. System Parameters OCM Call Classification screen
Valid entries Usage
0 to 15 0 is the least and 15 the most adjustment.
Valid entries Usage
y/n To use the default United States tone detection, set this field to
y. If you enter n, the US Special Information Tones (SIT)
Algorithm field appears.
Valid entries Usage
yTo use the United States (SIT) tone characteristics for SIT tone
detection.
nThe system treats tones with the administered tone name
“intercept” as if they were SIT VACANT, and treats tones with
the administered tone name “information” as if they were SIT
UNKNOWN.
Page 2 of 9
SYSTEM PARAMETERS OCM CALL CLASSIFICATION
Tone Name Instance Tone Cadence Duration Duration
Continuous Step Minimum Maximum
_________ _____ ___ 1. on _____ _____
2. off _____ _____
3. on _____ _____
4. off _____ _____
5. on _____ _____
6. off _____ _____
7. on _____ _____
8. off _____ _____