DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Managing trunks
357Removing trunks from a trunk group
12
5. In the Mode field, type e&m.
!CAUTION:
An entry in this field is only required for some circuit packs. Dip
switch settings on the circuit pack co ntrol the signalling mode used on
the trunk group, so the entry in the Mode field must co rrespond to the
actual setting on the circuit pack.
6. In the Type field, type t1-comp.
An entry in this field is only required for some cir cuit packs.
7. Repeat steps 3–6, as appropriate, for the remaining trunks.
Notice that you can assign trunks in the same trunk group to ports on
different circuit packs.
8. Press ENTER to save your changes.
Removing trunks from a trunk group
Use this procedure to remove vacant trunk ports or to change the assignment of
existing trunks. To change the assignment of existing trunks, remove them from
their current trunk group and add them to the new group.
Instructions
Let’s remove trunks 5214 and 5215 from trunk group 5.
To remove trunks from trunk group 5:
1. Type change trunk-group 5 and press RETURN.
The Trunk Group screen appears.