Collecting billing information
445Forcing users to enter account codes
16
Instructions
In this example, we administer the system to force users in our North American
office to enter an account code before making international calls.
1. Type change system-parameters cdr and press RETURN.
The CDR System Parameters screen appears.
2. In the Force Entry of Acct Code for Calls Marked on Toll Analysis Form
field, type y.
3. In the CDR Account Code Length field, type 5.
4. Press ENTER to save your changes.
5. Type change toll 0 and press RETURN.
6. The Toll A naly sis screen appears.
7. In the first available Dialed String field, type 011.
This is the international access code for this office.
8. In the Total Min and Max columns, type 10 and 18, respectively.
This is the minimum and maximum number of digits the system will
analyze when determining how to handle the call.
9. In the Toll List and CDR FEAC columns, type x.
10. Press ENTER to save your changes.
change toll analysis Page 1 of 1
TOLL ANALYSIS Percent Full:_
Location:
Total Toll CDR <--Unrestricted Call List-->
Dialed String Min Max RCL List FEAC 1 2 3 4 5 6 7 8 9 10
0____________________ 1__ 1__ _ x _ _ _ _ _ _ _ _ _ _ _
01___________________ 9__ 17_ _ x x _ _ _ _ _ _ _ _ _ _
011__________________ 10_ 18_ _ x x _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _
_____________________ ___ ___ _ _ _ _ _ _ _ _ _ _ _ _ _