DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506   Issue 1
April 2000
Screen reference 
1010Trunk Group 
17
Field descriptions for page 3
The figure below shows a common configuration for page 3 of the Trunk Group 
screen when the Group Type field is co. This screen is only an example, and the 
fields shown below may change or disappear according to specific field settings.
Screen 212. Administrable Timers for Trunk Group
!CAUTION:
Customers: Do not change fields on this page withou t assistance from 
Lucent Technologies or your network service provider.
Send Incoming/Outgoing Disconnect Timers to 
TN465 Ports
The field appears only for a co, fx, or wats trunk group.
Valid entries Usage
y/n  Enter y if you want to send the incoming disconnect and 
outgoing disconnect timer values to the trunk group ports that 
are on a TN465 board.
add trunk-group next Page 3 of x
ADMINISTRABLE TIMERS       
Send Incoming/Outgoing Disconnect Timers to TN465 Ports? _
Outgoing Dial Guard(msec): _____
  Incoming Glare Guard(msec): _____ Outgoing Glare Guard(msec): _____
                                 Outgoing Rotary Dial Interdigit (msec): ____
       Ringing Monitor(msec): _____  Incoming Seizure(msec): ____
   Outgoing End of Dial(sec): ___   Outgoing Seizure Response(sec): ___
Programmed Dial Pause(msec): _____ Disconnect Signal Error(sec): ___
          Flash Length(msec): ____
END TO END SIGNALING
Tone (msec): ____ Pause (msec): 150 
OUTPULSING INFORMATION
PPS: 10 Make(msec): 40 Break(msec): 60  PPM? y Frequency: 50/12k