DEFINITY ECS Release 8.2
Administrator’s Guide
555-233-506 Issue 1
April 2000
Screen reference
586Data modules
17
Restart (T20) Timer (seconds)
The T20 timer is a DTE time-limit started when DTE issues a restart indication
and terminated when the restart request is rec eived or confirmed.
Reset (T22) Timer (seconds)
The T22 timer is a DTE time-limit start ed when DTE issues a reset indication a nd
terminated when the reset request is received or confirmed.
Screen 15-1. 7500 and World Class BRI Data Module
XID
(Exchange identification) Used with 7500 and World Class BRI Data Modules.
Used to identify layer 2 XID testing capabili ty.
Fixed TEI
Used with 7500 and World Class BRI Data Modules. Used to indicate whether the
endpoint has Fixed Terminal Equipment Identifier (TEI) capability. TEI identifies
a unique access point within a service. For Fixed TEI stations, the TEI must be
administered. Terminals with automatic TEI capability, the associated TEI is
assigned by the system.
Valid entries Usage
0 - 500
Valid entries Usage
0 - 500
Valid entries Usage
y/n Lucent recommends setting to n.
Valid entries Usage
y/n Enter y to indicate the endpoint has Fixed Terminal Equipment
Identifier (TEI) capability.
change data-module 30 Page 2 of 2
DATA MODULE
BRI LINK/MAINTENANCE PARAMETERS
XID? y Fixed TEI? n TEI: ___
MIM Support? y Endpt Init? y SPID: 300_____ MIM Mtce/Mgt? y