 | between an Entry into the L2 state and the first Power Trim in the | 
| 
 | L2 state and between two consecutive Power Trims in the L2 | 
| 
 | State. It ranges from 0 to 255 seconds. | 
| 
 | 
 | 
| Conf PML2 ATPR (dB/10) | PM configuration parameter, related to the L2 low power state. | 
| 
 | This parameter represents the maximum aggregate transmit | 
| 
 | power reduction (in dB) that can be performed through a single | 
| 
 | Power Trim in the L2 state. It ranges from 0 dB/10 to 310 dB/10. | 
| 
 | 
 | 
| Conf PML2 Min Rate(bps) | PM configuration parameter, related to the L2 low power state. | 
| 
 | This parameter specifies the minimum net data rate during the low | 
| 
 | power state (L2). The data rate is coded in bit/s, and can range | 
| 
 | from 0x1F40 (8000) bps to 0xFA000 (1024000) bps. | 
| 
 | 
 | 
| MSG Min Ds | Configures downstream overhead channel bandwidth. This | 
| 
 | feature is not supported by DSLPHY as yet. | 
| 
 | 
 | 
| Min Snr Mrg(dB/10) | Atuc Configured Minimum Signal/Noise Margin. This is the Noise | 
| 
 | Margin, the modem must achieve with a BER of 10 to the power  | 
| 
 | or better, to successfully complete initialization. The default value | 
| 
 | mentioned is an indicative value only. | 
| 
 | 
 | 
| FrontEnd H/W Design | Front end hardware reference design | 
| 
 | 
 | 
| H/W Pwr Reduction | Hardware configuration parameter | 
| 
 | 
 | 
| GsUsBitSwap | This parameter enables/disables upstream bit swapping | 
| 
 | 
 | 
| Minimum INP | Parameter used to specify the minimum impulse noise protection | 
| 
 | for the downstream bearer channel. | 
| 
 | 
 | 
| PML2 Entry Thresh Rate | PM config param. L2 state entry data rate. | 
| 
 | 
 | 
| PML2 Exit Thresh Rate | PM config param. L2 state exit data rate. | 
| 
 | 
 | 
| PML2 Entry Rate Min Time | PM config param.Min L2 entry rate time | 
| 
 | 
 | 
| CabinetHsEnable | Enable/Disable HS tones in Cabinet mode | 
| 
 | 
 | 
| GsSeltLoopType | Conexant parameter that is used to specify the loop type for | 
| 
 | SELT. The default value mentioned is an indicative value only. | 
| 
 | 
 | 
| GsRxStartBinU1 | Conexant parameter that specifies lowest bin number allowed for | 
| 
 | Rx signal in G.Span Plus SUQ mode. By selecting the receive | 
| 
 | start and end bin numbers, the user can limit the bins for special | 
| 
 | configurations.(length = 4 bytes) | 
| 
 | 
 | 
| GsRxEndBinU1 | Conexant parameter that specifies highest bin number allowed for | 
| 
 | Rx signal in G.Span Plus SUQ mode. By selecting the receive | 
| 
 | start and end bin numbers, the user can limit the bins for special | 
| 
 | configurations.(length = 4 bytes) | 
| 
 | 
 | 
| PSD MoD Enable | Conexant parameter that is used to configure the switching point | 
| 
 | between  | 
| 
 | 
 | 
| PsdMod FallBackEnable | Conexant parameter used to enable Mask on Demand (MoD) | 
| 
 | fallback mode. When enabled, the system chooses MoD or the | 
| 
 | 
 | 
| IP DSLAM | 299 | 
| 
 | 
 |