GVRP, LACP

 

 

 

 

flow<trace-flow>

This indicates a Hexadecimal bitmask,

which sets the filter

 

for trace flow.

 

 

Type

: Optional

 

 

Valid values: 0x0 to 0xffffffff

 

 

 

 

level <trace-level>

This indicates a Hexadecimal bitmask,

which sets the filter

 

for trace level.

 

 

Type

: Optional

 

 

Valid values: 0x0 to 0xffffffff

 

 

 

syslognetstdout

This specifies the type of logging to be done. Incase net or

 

syslog is specified then dest and port must be specified.

 

Type: Optional

 

 

 

dest<ip-address>

This specifies the IP address for host for logging for trace

 

type syslog and net. It is invalid incase of trace type stdout

 

Type: Mandatory when type is modified to net or syslog;

 

else it is invalid

 

 

Valid values: Any valid class A/B/C IP address

 

 

port <port-number>

Port number on which, host is listening for trace info to be

 

logged incase of trace type syslog and net. It is invalid

 

incase of

trace type stdout

 

 

Type: Mandatory when type is modified to net or syslog;

 

else it is invalid

 

 

Valid values: 0-4294967295

 

 

 

 

 

Mode:

Super-User

Example:

$ modify trace cfg module GAG flow 0x1 level 0x1

Output :

Verbose Mode On

Module

Flow

Level

Type

Destn

Port

------------------------------------------------------------------------

 

 

 

 

GAG

0x0

0x0

Stdout

0.0.0.0

0

 

 

Set Done

 

 

 

 

 

 

 

Module

Flow

Level

Type

Destn

Port

------------------------------------------------------------------------

 

 

 

 

GAG

0x1

0x1

Stdout

0.0.0.0

0

 

 

 

 

 

 

 

 

 

 

IP DSLAM

 

 

 

 

 