vc <vc-val>

Name of the VC to be part of aggregation.

 

Type:

Create

--

Mandatory

 

 

 

Delete

--

Mandatory

 

 

 

Modify

--

Mandatory

 

 

 

Get

--

Optional

 

Valid values: 101 -206

 

 

 

dnstrmpriolist 0 1 2

This field specifies the downstream priorities with

3 4 5 6 7 none

which the specified VC interface shall be

 

associated under a VC Aggregation interface.

 

This field is used for demultiplexing downstream

 

traffic. A VC can be mapped to multiple priorities.

 

But not two VCs can be mapped to same priority.

 

Value None has special significance. It specifies

 

that this VC is part of VC Aggregation interface

 

but no priority is mapped to it.

 

Type:

Create

--

Optional

 

 

 

Modify

--

Optional

 

Default value: 8

 

 

 

 

 

upstrmdefprio

Priority parameter to be used for tagging the

<upstrmdefprio-val>

untagged upstream traffic coming on a VC.

 

Regeneration of priority at bridge level will be

 

done on the basis of this priority.If value None is

 

specified, then bridge port's defprio will be used

 

for tagging the untagged packets

 

Type:

Create

--

Optional

 

Modify

--

Optional

 

 

Valid values: 0 -8

 

 

 

Default value: 8

 

 

 

 

 

upstrmregenprio

Priority parameter to be used for retagging the

<upstrmregenprio-val>

tagged upstream traffic coming on a

 

VC.Regeneration of priority at bridge level will be

 

done on the basis of this priority.If value None is

 

specified, then bridge port's priority regeneration

 

map will be used.

 

 

 

Type:

Create

--

Optional

 

Modify

--

Optional

 

 

Valid values: 0 - 8

 

 

 

Default value: 8

 

 

 

 

 

 

 

 

 

 

646