Polycom RMX 1500 Flag name H323TIMERSSETINDEX, Flag name Disabledummyregistration, TimerK, 5000

Models: DOC2702A RMX 1500

1 1010
Download 1010 pages 2.36 Kb
Page 1010
Image 1010

Polycom RealPresence Collaboration Server (RMX) 1500/2000/4000 Administrator’s Guide

Table 1 SIP Timer Types & their Values (Continued)

SIP TIMER Types

Value (in milliseconds)

 

 

 

POLYCOM (flag default)

Standard Recommended

 

 

 

 

TimerK

5000

5000

 

 

 

Flag name: H323_TIMERS_SET_INDEX

Flag description: Enables or disables H.323 index timer according to standard or proprietary H.323 protocol.

Section CS_MODULE_PARAMETERS Possible values:

0 - Sets the H.323 index timer to Polycom proprietary (flag default setting)

1 - Sets the H.323 index timer based on the H.323 Standard recommendation. For homologation and certification testing, this flag must be set to 1.

Flag name: DISABLE_DUMMY_REGISTRATION

Flag description: Enables or disables SIP dummy registration on the domain.

Flag Section: MCMS_PARAMETERS_USER Possible values:

NO - Disables SIP dummy registration (flag default setting).

YES - Enables SIP dummy registration. For homologation and certification testing, the flag must be set to YES.

L-2