Appendix F-Secure Communication Mode
Polycom, Inc. F-19

Directory and Database Options

Ultra Secure Mode

Internal MCU database and Active Directory
Authentication is first attempted using the internal MCU database. If it is not successful
authentication is attempted using the Active Directory.

Standard Security Mode

Internal MCU database + External Database
First authentication is via the internal MCU database. If it is not successful, authentication is
via the External Database.
Internal MCU database + External Database + Active Directory
Management Logins
First authentication is via the internal MCU database. If it is not successful,
authentication is via the Active Directory.
Conference Queries (Chairperson Password, Numerical ID etc.)
First authentication is via the internal MCU database. If it is not successful,
authentication is via the External Database.
Guidelines
The MCU maintains a local record of:
Audit Events – users that generate these events are marked as being either internal
or external.
Successful user logins
Failed user login attempts
User passwords and user lockout policy for external users are managed via Active
Directory’s integration with the user’s host machine.
Enabling or disabling Active Directory integration does not require a reset.