Chapter 22-System Configuration Flags
Polycom, Inc. 22-21
CELL_IND_LOCATION Change the location of the display of Network Quality
Indicators displayed in the cells of the conference Video
Layout.
Default: TOP_RIGHT
Range:
BOTTOM_LEFT
BOTTOM_RIGHT
TOP_LEFT
TOP_RIGHT
CFG_KEY_ENABLE_FLOW_
CONTROL_REINVITE
Used to enable or disable sending a re-INVITE to endpoints to
adjust their data rate. When set to YES, re-INVITE is used for
endpoints that do not support flow control in SIP using either
the Information or RTCP Feedback mechanisms.
Default: NO.
CONF_GATHERING_DURAT
ION_SECONDS
The value of this System Flag sets the duration of the
Gathering Phase in seconds. The Gathering Phase duration
of the conference is measured from the scheduled start time
of the conference.
Range: 0 - 3600
Default: 180
For more information see "Video Preview” on page 4-26.
CP_REGARD_TO_INCOMIN
G_SETUP_RATE
For use in the Avaya Environment.
If set to YES, the RMX calculates the line rate for incoming
calls in CP conferences, according to the line rate which is
declared by the endpoint in the H.225 setup message.
If set to NO, the rate is calculated according to the conference
line rate regardless of the rate in the H.225 setup message.
Default: YES.
CPU_BONDING_LINK_MON
ITORING_FREQUENCY
Used when using the MII Monitor for troubleshooting
networks.This flag sets the MII Polling Interval in milliseconds.
A value of zero disables MII monitoring.
Default: 100
Table 22-2 Manually Added System Flags – MCMS_PARAMETERS (Continued)
Flag Description