Polycom RMX 1500, DOC2702A manual Bonding Phone Number Phone number for Bonding dial-out calls

Models: DOC2702A RMX 1500

1 1010
Download 1010 pages 2.36 Kb
Page 826
Image 826

Polycom RealPresence Collaboration Server (RMX) 1500/2000/4000 Administrator’s Guide

Table C-19Event Fields for Event 18 - NEW UNDEFINED PARTICIPANT (Continued)

Field

Description

 

 

Chair

Not supported.

 

Always contains the value 0.

 

 

Video Protocol

The video protocol, as follows:

 

1

- H.261

 

2

- H.263

 

4

- H.264

 

255 - Auto

 

 

Broadcasting

The broadcasting volume assigned to the participant.

Volume

The value is between 1 (lowest) and 10 (loudest).

 

Each unit movement increases or decreases the volume by 3 dB.

 

 

Undefined

Indicates whether are not the participant is an undefined participant, as

Participant

follows:

 

0

- The participant is not an undefined participant.

 

2

- The participant is an undefined participant.

 

 

Node Type

The node type, as follows:

 

0

- MCU

 

1

- Terminal

 

 

Bonding Phone

Note: This field is only relevant to ISDN/PSTN participants.

Number

The phone number for Bonding dial-out calls.

 

 

Bonding is a communication protocol that aggregates from two up to thirty 64

 

Kbps B channels together, to look like one large bandwidth channel.

 

 

Video Bit Rate

The video bit rate in units of kilobits per second.

 

A value of 4294967295 denotes auto, and in this case, the rate is computed

 

by the MCU.

 

 

IP Address

Note: This field is only relevant to IP participants.

 

The IP address of the participant.

 

An address of 4294967295 indicates that no IP address was specified for the

 

participant, and the gatekeeper is used for routing. In all other cases the

 

address overrides the gatekeeper.

 

 

Signaling Port

Note: This field is only relevant to IP participants.

 

The signaling port used for participant connection.

 

A value of 65535 is ignored by MCU.

 

 

 

C-28

Polycom, Inc.