Polycom RealPresence Collaboration Server (RMX) 1500/2000/4000
22-18 Polycom, Inc.
3To modify a flag value, double-click or select the flag and click the Edit Flag button.
4In the New Value field, enter the flag’s new value.
5Click OK to close the Update Flag dialog box.
6Repeat steps 2–4 to modify additional flags.
7Click OK to close the System Flags dialog box

Manually Adding and Deleting System Flags

To add a flag:
1In the System Flags dialog box, click the New Flag ( ) button.
The New Flag dialog box is displayed.
2In the New Flag field enter the flag name.
3In the Value field enter the flag value.
USER_LOCKOUT_DURATIO
N_IN_MINUTES
Defines the duration of the Lockout of the user.
Value: 0 - 480
0 means permanent User Lockout until the administrator re-
enables the user within the system.
Default: 0
USER_LOCKOUT_WINDOW
_IN_MINUTES
Defines the time period during which the three consecutive
Login failures occur.
Value: 0 - 45000
0 means that three consecutive Login failures in any time
period will result in User Lockout.
Default: 60
Table 22-1 System Flags – MCMS_PARAMETERS (Continued)
Flag Description
For flag changes (including deletion) to take effect, reset the MCU. For more information see
"Resetting the RMX” on page 21-69.