Chapter 12: Trunk Configuration

Triton T1/E1 Trunk Properties

To open a configuration dialog box for a Triton T1/E1 channel, do one of the following:

If you’re in the Trunk Configuration window, select a Triton T1/E1 channel from the trunk channels list, then click the Trunk Properties button, or just double-click the channel in the list.

If you’re in the Trunk View window, right-click the channel and select Channel Properties.

Figure 6. Triton T1 Configuration dialog box

Following are the parameters for the Triton T1 Configuration dialog box:

Parameter

Description

 

 

 

T1 robbed-bit signaling

 

 

Protocol

You can set Protocol to one of the following:

 

E&M Wink Start (default)

 

E&M Immediate Start

 

Ground Start

 

Loop Start

 

For signaling from one board to another, only E&M Wink

 

Start is supported. Loop Start, Ground Start, and E&M

 

Immediate Start protocols cannot be used for interfacing

 

between two boards.

 

 

Dialing Delay

Specifies the delay, in milliseconds, after trunk seizure and

 

before digit dialing. This configuration will slow down the

 

system transmitting digits to the CO by a defined delay to

 

avoid missing digits. Do not change this value unless advised.

 

 

 

Caller ID and DID Collection

AltiWare ACM 5.1 Administration Manual 157

Page 171
Image 171
AltiGen comm ACM 5.1 Triton T1/E1 Trunk Properties, Parameter Description T1 robbed-bit signaling Protocol, Dialing Delay