Chapter 12: Trunk Configuration

 

 

 

Parameter

Description

 

 

 

 

 

 

 

Incoming Ring

Single—Default setting for North America

 

 

Double—For countries using Ring-Ring-Silent type of ring

 

 

pattern

 

 

 

 

Impedance

The resistance of electrical current to alternating current,

 

 

measured in Ohms. Impedance occurs when power or

 

 

signal is transferred from one circuit to another. When a

 

 

trunk interface impedance is greatly mismatched with the

 

 

CO analog line, it may result in static noise and echo heard

 

 

by IP phone users. The system automatically selects the

 

 

impedance profile that best matches the Triton trunk

 

 

interface with the CO. In the rare case where you are not

 

 

getting the best match, you can disable this feature by

 

 

checking Disable Impedance Match During System

 

 

Startup, and you can set the Impedance manually.

 

 

 

 

Match Impedance

Changes the Impedance setting to the best match for the

 

button

selected trunk channel, and then measures noise and

 

 

returned echo with this impedance setting. Results are

 

 

displayed in the Diagnosis section of the dialog box. The

 

 

system automatically runs a matching test upon system

 

 

startup, unless you disable the feature. If later you

 

 

connect a new analog line to an empty port or replace an

 

 

existing line, you need to click this button to best match

 

 

the impedance.

 

 

 

 

Match Result button

Shows the result obtained the last time the Match

 

 

Impedance button was clicked for that trunk.

 

 

 

 

Disable Impedance

Check to disable automatic impedance matching during

 

Match During System

system startup.

 

Startup

 

 

 

 

 

Caller ID Receiving

Select as None, FSK or DTMF for receiving caller ID

 

 

digits. For North America, the caller ID is FSK signal on

 

 

analog trunk.

 

 

 

 

Centrex Flash

Specifies the Flash Duration time in milliseconds, with a

 

Duration (ms)

range from 150 ms to 1000 ms.

 

 

 

 

Out of Service With

When checked, if the trunk is set to Out of Service, the

 

Trunk Seizure

system will busy out the trunk. The CO will treat this trunk

 

 

as a busy line and WILL NOT place a call to this trunk. (By

 

 

default, this option is unchecked.)

 

 

 

 

Enable Dial Tone

When enabled, the trunk channel must detect outgoing

 

Detection (Outgoing)

dial tone prior to making the call.

 

 

 

 

Enable Answer

Enables a timeout period of 2 seconds (for ignoring false

 

Debounce (Incoming)

CO disconnect signal), after answering an incoming call.

 

 

 

 

Loop Break Duration

Disconnects signal if CO breaks loop current. You can set

 

(ms)

the duration from 200 to 1000 ms. 600 ms is common in

 

 

North America.

 

 

 

 

AltiWare ACM 5.1 Administration Manual 161

Page 175
Image 175
AltiGen comm ACM 5.1 manual Parameter Description Incoming Ring, Caller ID Receiving, Centrex Flash, Duration ms