Appendix A: E1-R2 and E1 ISDN PRI Installations

2.In the Board Configuration window, double-click the channel group to open the Channel Group Configuration dialog box.

Figure 1. Physical Layer

Consult your CO for “Frame Type,” “Line Code,” or “Zero Code Suppression.” Do not check the System Clock Master check box because the CO is a clock provider, and the AltiGen system is synchronized to the CO. If all configurations are correct, the status should be shown as “OK,” as in Figure 1.

3.Click the Protocol button in the Channel Group Configuration dialog box to open the Protocol Configuration window.

Figure 2. Data Link Layer

4.Select E1 CAS as the Span Type, and select the Switch Mode according to your country in the E1 R2 Setting field, and click OK.