Chapter 12: Trunk Configuration

Parameter

Description

 

 

 

 

Tone Disconnect

Busy tone (reorder tone, fast busy tone, error tone, and so

 

on) or dial tone (continuous tone, and so on). This should

 

be used in conjunction with drop in loop current. For COs

 

who cannot guarantee loop break, this may be the only

 

option.

 

 

Receiver/

Slide setting adjusts the gain from -6 dB to 6 dB for every

Transmission Gain

Triton Analog Trunk channel.

 

The gain is not adjustable, by default. The user needs to

 

run the diagnosis first to change the gain. The diagnosis

 

process determines the max gain based on the diagnosis

 

results.

 

The default setting is 0 dB, and it is highly recommended

 

that you not change this setting.

 

Caution! Setting the volume too high will cause distortion

 

in voice quality and/or missed DTMF digits.

 

 

Trunk to Trunk Gain

This configuration is to set Gain for calls that involve two

 

analog trunks (one in and one out). Because an analog

 

trunk typically has energy loss of 3-12 dB, a two-trunk

 

operation, like VM out call and MobileExt, may have low

 

volume issues because energy loss is doubled. This

 

configuration can compensate the energy loss. The valid

 

range is 0 to 6 dB. Recommended value is 3 dB.

 

Caution: Setting the Gain too high may cause distortion

 

in voice quality and DTMF tone. Your CO may not be able

 

to recognize the dialing number if DTMF tone is distorted.

 

 

Last Diagnosis Time

The last time the Diagnosis button was clicked.

 

 

Diagnose button

Use this button to view the Noise Level, Echo Return Loss,

 

and Hybrid Echo Return Loss, measured using the current

 

Impedance setting.

 

 

Noise Level

The noise level (displayed after you click the Diagnose

 

button or the Match Impedance button). Acceptable

 

range for Noise Level is less than -67 dBm in value. For

 

example, Noise Level of -72 dBm is good and -63 dBm is

 

poor. You may experience high background noise and low

 

voice volume if Noise Level is poor.

 

 

Echo Return Loss

The measurement for echo return loss (displayed after you

 

click the Diagnose button or the Match Impedance

 

button). Acceptable range for Echo Return Loss is less than

 

-12 dB. For example, Echo Return Loss of -19 dB is good

 

and -8dB is poor. The IP phone users may hear their voice

 

coming back (echo) if Echo Return Loss is poor.

 

 

Hybrid Echo Return

The measurement for hybrid echo return loss (displayed

Loss

after you click the Diagnose button or the Match

 

Impedance button). Acceptable range for Hybrid Echo

 

Return Loss is less than -6 dB.

 

 

162AltiWare ACM 5.1 Administration Manual