Chapter 15: Extension Configuration

Parameter

Description

 

 

 

 

Ringing Frequency

Select the frequency in Hz that is necessary for the

(Hz)

equipment attached to this line: 28 (default) or 20.

 

 

Line Disconnect

The loop current break desired for answering

Signal

supervision. Range 600-1000 ms (1000 ms is

 

default).

 

 

Caller ID

Specifies how Caller ID will be detected:

Transmission

• CID between 1st and 2nd ring - Caller ID is

Methods

received between first and second ring. (Most

 

 

common in US/Canada)

 

DT-AS+CID prior to ringing - Dual Tone Alerting

 

Signal Caller ID is received prior to ringing.

 

RP-AS+CID prior to ringing - Ring Pulse Alerting

 

Signal Caller ID is received prior to ringing.

 

 

Receive from phone

Range -3 ~ +3 db

(dB Gain)

You can decrease or increase the extension phone's

 

 

talk volume with this setting. Default is 0 dB.

 

 

Transmit to phone

Range -3 ~ +3db

(dB Gain)

You can decrease or increase the extension phone's

 

 

receiving volume with this setting. The volume will

 

be lower or higher for the extension user. Default is

 

0 dB.

 

 

IP Extension Configuration

See “Setting Up IP Extensions” on page 225 for information on configuring this section of the Extension Configuration General tab.

Phone Display Options

For analog and IP phones, the administrator can select what information is to be displayed.

Depending on the number of display lines on the LCD, the phone can be set up to show two lines of specific caller information on the display.

In the Phone Display field, use the Number Line and Name Line drop-down lists to select the caller information to display:

Caller Number

Caller Name

DNIS Number

DNIS Name

IVR Data

User Data

202AltiWare ACM 5.1 Administration Manual